ENCP 80-250 L

1.00

Ask For More Informations

ENCP 80-250 L Centrifugal Pump


ENCP 100-200 L Refurbished

ENCP 80-250 L

Refurbished ETANORM Pump With 24 Months Warranty.

Operating Data:

Q : Up to 490 US g.p.m

H:  Up to 80 feet

t:  -30 ºC to +140 ºC

Power:  Up to 15 HP/ 11 KW

Suction Size:   4″

Discharge Nozzle Size:   3″

 

27 in stock

Description

ENCP Field of Applications:

  • Water Supply
  • Fire-Fighting Systems
  • Sprinkling
  • Irrigation
  • Drainage
  • Heating
  • Air-Conditioning System
  • Drinking Water
  • Cooling Water
  • Swimming Pool Water
  • Brine
  • Oils

Fluid:

Pump liquid not chemically or mechanically aggressive to the pump materials.

Pump Design:

Horizontal volute casing pump, single-stage with power ratings and main dimensions to EN 733 with bearing bracket, in back pull-out design.

shaft with replaceable shaft sleeve/shaft protecting sleeve in the shaft seal area. volute casing and impeller with replaceable wear rings. volute casing with integrally cast pump feet.

Bearings:

Deep-groove ball bearings, grease -lubricated.


Models Parameters:

Model:   ENCP 80-250 LA

Min . Max Flow (US g.p.m): 175-240-300-360-425-480-540-590

Max. Min Head (Ft):   85-81-80-78-75-71-66-60

Motor Requirement (HP/KW): 15 / 11

Voltage: 380 VAC-415 VAC


Model:   ENCP 80-250 LB

Min . Max Flow (US g.p.m): 175-240-300-360-425-480-540-590

Max. Min Head (Ft):   75-74-73-70-66-61-00-00

Motor Requirement (HP/KW): 10 / 7.5

Voltage: 380 VAC-415 VAC


Model:   ENCP 80-250 LC

Min . Max Flow (US g.p.m): 175-240-300-360-425-480-540-590

Max. Min Head (Ft):   60-58-56-54-50-00-00-00

Motor Requirement (HP/KW): 7.5 / 5.5

Voltage: 380 VAC-415 VAC


Model:   ENCP 80-250 LD

Min . Max Flow (US g.p.m): 175-240-300-360-425-480-540-590

Max. Min Head (Ft):   53-51-47-44-00-00-00-00

Motor Requirement (HP/KW): 5.5 / 4

Voltage: 380 VAC-415 VAC

Additional information

Suction Size (inches):

4"

Discharge Size (Inches):

3"

R.P.M / Pole

1450 / 4 Pole